Pages

Tuesday, August 2, 2011

Regulation of cholesterol synthesis


Regulation of cholesterol synthesis

Biosynthesis of cholesterol is directly regulated by the cholesterol levels present, though the homeostatic mechanisms involved are only partly understood. A higher intake from food leads to a net decrease in endogenous production, whereas lower intake from food has the opposite effect. The main regulatory mechanism is the sensing of intracellular cholesterol in theendoplasmic reticulum by the protein SREBP (sterol regulatory element-binding protein 1 and 2). In the presence of cholesterol, SREBP is bound to two other proteins: SCAP (SREBP-cleavage-activating protein) and Insig1. When cholesterol levels fall, Insig-1 dissociates from the SREBP-SCAP complex, allowing the complex to migrate to the Golgi apparatus, where SREBP is cleaved by S1P and S2P (site-1 and -2 protease), two enzymes that are activated by SCAP when cholesterol levels are low. The cleaved SREBP then migrates to the nucleus and acts as a transcription factor to bind to the SRE (sterol regulatory element), which stimulates the transcription of many genes. Among these are the low-density lipoprotein (LDL) receptor and HMG-CoA reductase. The former scavenges circulating LDL from the bloodstream, whereas HMG-CoA reductase leads to an increase of endogenous production of cholesterol. A large part of this signaling pathway was clarified by Dr. Michael S. Brown and Dr. Joseph L. Goldstein in the 1970s. In 1985, they received the Nobel Prize in Physiology or Medicine for their work. Their subsequent work shows how the SREBP pathway regulates expression of many genes that control lipid formation and metabolism and body fuel allocation.
Cholesterol synthesis can be turned off when cholesterol levels are high, as well. HMG CoA reductase contains both a cytosolic domain (responsible for its catalytic function) and a membrane domain. The membrane domain functions to sense signals for its degradation. Increasing concentrations of cholesterol (and other sterols) cause a change in this domain's oligomerization state, which makes it more susceptible to destruction by the proteosome. This enzyme's activity can also be reduced by phosphorylation by an AMP-activated proteinkinase. Because this kinase is activated by AMP, which is produced when ATP is hydrolyzed, it follows that cholesterol synthesis is halted when ATP levels are low.

Sunday, July 17, 2011

Biosynthesis

All animal cells manufacture cholesterol with relative production rates varying by cell type and organ function. About 20–25% of total daily cholesterol production occurs in the liver; other sites of higher synthesis rates include the intestines, adrenal glands, and reproductive organs. Synthesis within the body starts with one molecule of acetyl CoA and one molecule of acetoacetyl-CoA, which are hydrated to form 3-hydroxy-3-methylglutaryl CoA (HMG-CoA). This molecule is then reduced to mevalonate by the enzyme HMG-CoA reductase. This step is the regulated, rate-limiting and irreversible step in cholesterol synthesis and is the site of action for the statin drugs (HMG-CoA reductase competitive inhibitors).
Mevalonate is then converted to 3-isopentenyl pyrophosphate in three reactions that require ATP. Mevalonate is decarboxylated to isopentenyl pyrophosphate, which is a key metabolite for various biological reactions. Three molecules of isopentenyl pyrophosphate condense to form farnesyl pyrophosphate through the action of geranyl transferase. Two molecules of farnesyl pyrophosphate then condense to form squalene by the action of squalene synthase in the endoplasmic reticulum. Oxidosqualene cyclase then cyclizes squalene to form lanosterol. Finally, lanosterol is then converted to cholesterol.
Konrad Bloch and Feodor Lynen shared the Nobel Prize in Physiology or Medicine in 1964 for their discoveries concerning the mechanism and regulation of cholesterol and fatty acid metabolism.

Form : http://en.wikipedia.org/wiki/Cholesterol

Tuesday, June 28, 2011

Omron HBF-306C Fat Loss Monitor, Black


Product Features

  • Analyzer measures your body fat with a gentle, micro electrical current
  • Two modes -- athletic and normal -- provide accurate results based on your exercise regiment
  • Delivers measurement results for Bi method (Bioelectrical Impedance Method) and BMI (Body Mass Index)
  • Delivers results in approximately seven seconds
  • Features a nine person memory profile for the whole family
  • 9 person profile
  • Accurate readings in seconds
  • Athlete mode for accurate results for athletes
  • Measures 2 fitness indicators: body fat percentage and body mass index (BMI)
  • Monitor your progress in losing body fat


Product Description

Amazon.com Product Description

The Omron HBF-306C Body Fat Analyzer measures your body fat with a gentle, micro electrical current -- don't worry, you won't feel it. The key to long-term exercise success is accurate body fat composition measurement. This handheld body fat analyzer is an affordable and easy way to measure your body fat in the privacy of your own home. After inputting the data, a measurement can be started by simply holding the grip electrodes and pressing the start button. And since the analyzer is built with a nine person profile memory, each member of your family or team can track the success of their individual exercise routines.


The Omron HBF-306C measures body fat with a micro electrical current. Detailed view.


The screen displays body fat measurements and other data. Detailed view.


Easy-to-use, handheld design.
The HBF-306C features two modes -- athlete and normal -- for accurate results. The device is a breeze to use, and it returns measurement results in seven seconds for both Bi method (Bioelectrical Impedance Method) and BMI (Body Mass Index). The unit displays the measured value of your body fat percentage through the BMI method, and indicates the body mass in for ranges from low, normal, high, and very high according to the BMI value.
What is the Bioelectrical Impedance Method?
Muscles, blood vessels and bones are body tissues having a high water content that conduct electricity easily. Body fat is tissue that has little electric conductivity. The Body Fat Analyzer sends an extremely weak electrical current of 50 kHz and 500 µA through your body to determine the amount of fat tissue. This weak electrical current is not felt while operating the Body Fat Analyzer. The Bioelectrical Impedance Method safely combines the electric resistance with the distance of the electricity conducted. Correct posture and consistent measuring conditions need to be maintained for the best results.
Operating the Analyzer
To use the HBF-306C you must first set your personal datYou must first select between the Normal and Athlete modes. To determine if you should select Normal or Athlete, you must calculate your FIT index by using the following formula:
  • FIT Index = Frequency x Intensity x Time
Frequency is a single digit number from one to five that represents your frequency of exercise. If you exercise daily or almost daily, then use the number five; three to four times per week use four; one to two times per week use three; a few times per month use two; and for less than once a month use one. If you workout vigorously, then you use the number five to represent your intensity level; if you workout with moderate or light effort, use the number four. Meanwhile, time is a single digit number from four to one that represents the duration of your workout. If you exercise for 45 minutes or more, then use the number four; 30-44 minutes use three; 15-29 minutes use two; and for less than 15 minutes use one. For example, if you run five times a week for 30 minutes, your FIT index would be 75 (5 x 5 x 3 = 75) and you would select the Athlete setting. If your FIT index is greater than 60, you should select the Athlete setting. Any number below would demand a normal setting.
After determining your FIT index and selecting between the Athlete and Normal setting, the remaining personal data is very straightforward. Simply enter your height, weight, age and gender. When all the data is fixed and stored, the analyzer screen will display "Ready," and you'll be ready to take your first body fat measurements.
Note: For the following cases, the body fat percentage measured by this unit may significantly differ from the actual body fat percentage.
  • Children in a growth stage
  • Elderly people and post-menopausal women
  • People with a fever
  • People who have swelling
  • Patients with osteoporosis who have very low bone density
  • Bodybuilders or professional athletes
  • Patients undergoing dialysis



Product Details

  • Product Dimensions: 9 x 2 x 6 inches ; 12.8 ounces
  • Shipping Weight: 1.1 pounds (View shipping rates and policies)
  • Shipping: This item is also available for shipping to select countries outside the U.S.
  • ASIN: B000FYZMYK
  • UPC: 073796306304
  • Item model number: HBF-306C
  • Batteries: 2 AAA batteries required. (included)



Omron HBF-510W Full Body Composition Monitor with Scale




undefined)

Product Features

  • Better accuracy due to full body sensing, with hand to foot technology
  • Monitors Body Fat Percentage
  • Body Mass index (BMI)
  • Monitors Body Weight
  • Four Person Profile

Product Description

New Advanced Accuracy
Full Body Sensing
Provides comprehensive understanding of your body composition to help you reach your fitness goals.
Contents:
1 Monitor / Scale
4 AA Batteries
1 Instruction Manual
Advanced Accuracy
Full body sensing is more accurate than measuring with fee alone.
5 Fitness Indicators
Body Fat
Track your body fat percentage... and get excited as it trends down!
Visceral Fat
Work on lowering the fat around your internal organs to help reduce your risk of high cholesterol, heart disease and type 2 diabetes.
BMI (Body Mass Index)
Get a better picture of your ideal weight by seeing an automatic computation of your height/weight ratio.
Skeletal Muscle
Watch your muscle mass build by the numbers, and use this data to minimize "rebound" weight gain in the future.
Body Weight
Still an important standard of fitness, especially in combination with your other fitness indicators.
Measuring Your Fitness Easily and Accurately!
Omron Introduces Full Body Sensing.
Throughout the day, your body composition can change. Omron's Full Body Sensing advanced technology is more accurate because it measures your whole body composition - from arm to foot - compared t foot-to-foot monitors. Seconds after you step on the lower sensor pads and lift the upper sensor bar, your personalized Fitness Indicators are automatically calculated. Whenever you take a measurement, you can trust Omron's clinically-proven technology to deliver precise and customized information. Daily reinforcement for a fit lifestyle!
Model
HBF-510W
Display
Weight:
0 to 330 lb. with 0.2 lb. increments (0 to 150 kg with 0.1 kg increments)
Body Fat Percentage:
5.0 to 60.0% with 0.1% increments
Skeletal muscle percentage:
5.0 to 50.0% with 0.1% increments
BMI:
7.0 to 90.0 with 0.1 increments
Visceral fat level:
30 levels with 1 level increments
Body fat percentage and skeletal muscle p

Product Details

  • Product Dimensions: 13.2 x 13.5 x 13.6 inches ; 8 ounces
  • Shipping Weight: 5.7 pounds (View shipping rates and policies)
  • Shipping: This item is also available for shipping to select countries outside the U.S.
  • ASIN: B001IV61J4
  • UPC: 073796265106 002765892272
  • Item model number: HBF-510W
  • Batteries: 4 AA batteries required.